Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the acf domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/yuzantech.com/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the unlimited-elements-for-elementor domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/yuzantech.com/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the dynamic-content-for-elementor domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/yuzantech.com/wp-includes/functions.php on line 6131
Data Center Management System – Zhejiang Yuzan Tech
gsfm (1)
Yuzan Tech Strengthens Global Presence with Intelligent Power Environment Solutions
Data-Center-Management-System-1
Passive Bluetooth Lock Intelligent Management System Makes a Grand Debut, Ushering in a New Era of Battery-Free Operation and Maintenance Safety Management
YZIBx-Series-Intelligent-Circuit-Breaker-Products-1-1024x769
Intelligent Circuit Breaker Series: The Smart Core of Modern Power Distribution

ABOUT US

About Us - Introducing our team,
mission, and values.

Data Center Management System

Model

DS818

Parameters

Item Specification
Operating Voltage DC12V
Operating Current ≤ 0.45A
Bolt Bearing Capacity 20 N·m
System Operating Temperature -20 ~ 60°C

 

Item Network Controller Node Controller
Operating Voltage AC220V DC12V
Unlocking Current ≤5A ≤1A
Standby Current <0.25A ≤ 0.025A
Communication Method CAN, TCP CAN
Baud Rate 100 Kbps 100 Kbps
Network Controller

Technical Parameters:

Operating Voltage: AC220V

Operating Current: ≤5A

Standby Current: <0.25A

Communication Method: CAN, TCP

Baud Rate: 100Kbps

 

Node Controller

Technical Parameters:

Operating Voltage: DC12V

Unlocking Current: ≤1A

Standby Current: ≤0.025A

Communication Method: CAN

Baud Rate: 100Kbps