| Name |
Parameter Example/Range |
| Battery Pack Voltage Acquisition |
2 channels |
| Battery Pack Current Acquisition |
2 channels |
| Temperature Acquisition |
1 channel |
| COM-BUS Interface |
1 channel (RJ11 Interface, supporting loopback) |
| RX485 Interface |
2 channels (supporting parallel connection) |
| Battery Pack Terminal Voltage Sampling Range |
0~70V |
| Battery Pack Terminal Voltage Resolution |
0.1V |
| Battery Pack Terminal Voltage Measurement Accuracy |
0.5% |
| Current Acquisition Range |
0-5000A (Configurable according to sensors) |
| Current Resolution |
0.1A |
| Current Measurement Accuracy |
0.5% |
| Temperature Measurement Range |
-10~80℃ |
| Temperature Measurement Accuracy |
±1℃ |
| Power Supply Type |
DC48V |
| Power Supply Power |
3W |
| Number of Monitored Modules |
Supports access of 250 XN200 monitoring modules |
| Communication Protocol |
Standard MODBUS Protocol |
| Operating Temperature |
-5℃~50℃ |
| Relative Humidity |
5%~90% |
| Installation Method |
Screw fixation or wall-mounted |