YZIBx Series Intelligent Circuit Breaker Products

Model

YZIB3-63
YZIB5-63
YZIB3-80
YZIB5-100

Parameters

MODEL YZIB3-63

YZIB5-63

YZIB3-80 YZIB5-100
Parameters Pole Number 1P, 1P+N, 3P, 3P+N
Rated Voltage Ue(V) AC230 (1P, 1P+N), (customizable)

AC400 (3P, 3P+N) (customizable)

Rated Current (A) 6, 10, 16, 20, 25, 32, 40, 50, 63 70, 80 70, 80, 100
Rated Insulation Voltage Ui(V) 500
Rated Impulse Withstand Voltage Uimp (kV) 4
Rated Ultimate Short-Circuit Breaking Capacity 10 6
Rated Service Short-Circuit Breaking Capacity 7.5 6
Rated Operating Frequency f(Hz) 50/60
Release Type Type B, Type C, Type D
Mechanical Life (Times) 20000
Electrical Life (Times) 10000
Protection Functions Overload Delay Protection No action within 1h (2h) when energized at 1.13In; action within 1h (2h) when energized at 1.45In; 2h for products ≥80AAction within (1~60)s when energized at
55In and In≤32A; action within (1~120)s when In>32A
Short-Circuit Instantaneous Protection No action within 100ms when energized at Type B (3In), Type C (5In), Type D (10In)
Action within 100ms when energizedat Type B (5In), Type C (10In), Type D (15In)
Electronic Overload Protection Adjustable from 1A~1.2In, default action at 1.2In
Over-Voltage Protection Adjustable from 240~300V, default action at 275V
Under-Voltage Protection Adjustable from 150~200V, default action at 160V
Phase Failure Protection For 3P+N products, the circuit breaker acts (≤1s) when any phase is missing
Over-Temperature Protection Adjustable from 1~120℃, default action at 90℃
Power Limitation Adjustable from 220~1.5Pn, default action at 1.5Pn
Arc Fault Protection (Optional □) The circuit breaker trips to protect when an arc short-circuit fault occurs
Three-Phase Unbalance Protection (Optional □) For 3P+N products, the circuit breaker trips to protect when current is unbalanced
Remote Control Remote Tripping Remote control of circuit breaker tripping via Web terminal or APP
Remote Closing Remote control of circuit breaker closing via Web terminal or APP
Measurement Voltage 0.7Un≤U≤1.3Un, accuracy ±0.5%
Current Accuracy ±1.5% when I≤0.05In; accuracy ±0.75% when 0.05In<I≤0.2In; accuracy ±0.5% when 0.2In<I≤1.2In
Power Accuracy ±2% when 0.05In≤I≤0.1In; accuracy ±1% when 0.1In<I≤1.2In
Electrical Energy Accuracy ±2% when 0.05In≤I≤0.1In; accuracy ±1% when 0.1In<I≤1.2In
Communication Communication Interface RS485 (Standard Configuration)
Communication Protocol Modbus-RTU
Communication Baud Rate Default 9600bps, optional 2400bps, 4800bps, 9600bps
Product Installation Dimensions

YZIB3-Dimension-Drawing

YZIB5-Dimension-Drawing

YZIB5S-Dimension-Drawing

YZIB5T-Dimension-Drawing

Related Products

Tell Us Your Requirements Questions Needs Ideas Plans



Seraphinite AcceleratorOptimized by Seraphinite Accelerator